Senin, 21 Maret 2016

BRAND Bottle-top burette Titrette®


Bottle-top burette
Titrette®
Titrette® – the first bottle-top burette to satisfy Class A error limits for glass burettes!   
It is also remarkable for its easy dropwise titration, compact design, ultra-high precision, replaceable piston/cylinder assembly and an optional PC interface.
With the Titrette® bottle-top burette, you can titrate quickly and reliably with the highest precision, even in close quarters, with no power hookup needed – in the lab, in production, or in the field.
  
Click here to see useful Utility Videos with the Titrette®
   
    

The bottle-top burette Titrette® in the press

Experience report Titrette®
  "Titration with Alcoholic Potassium
  Hydroxide Solution"
  (published in G.I.T. Laboratory Journal
  09-10/2009, p 37, GIT VERLAG GmbH
  & Co. KG, Darmstadt)
Professional article Titrette®
  "Titrations Fast, Simple, Reliable
  and Accurate"


  (published in G.I.T. Laboratory Journal
  3-4/2009, p 26, GIT VERLAG GmbH &
  Co. KG, Darmstadt)


Titrette®
Technical Data

Comparison of error limits

  Bottle-top burette Titrette®Bottle-top burette
acc. to DIN EN ISO 8655-3
Glass burettes
Class A acc.
DIN EN ISO 385
Volume
ml
Partial volume
ml
A*CV*A*CV*EL**
≤± %≤± µl≤ %≤ µl≤± %≤± µl≤ %≤ µl± µl
10100.10100.0550.3300.11020
50.20100.1050.6300.21020
11.00100.5533011020
25250.07180.02560.2500.12530
12.50.14180.0560.4500.22530
2.50.70180.25625012530
50500.06300.02100.21000.15050
250.12300.04100.41000.25050
50.60300.2010210015050
*   A  = accuracy. CV = coefficient of variation
** EL = error limit (EL = A + 2CV)

The maximum resolution of the display:
10 ml instrument: 0.001 ml
25 ml instrument: 0.001 ml, above 20 ml titration volume 0.01 ml
50 ml instrument: 0.002 ml, above 20 ml titration volume 0.01 ml

Range of application

The instrument can be used for the following titration media (maximum concentration 1 mol/l):
Acetic acidIron (II) sulfate solutionSilver nitrate solution*
Alcoholic potassium hydroxide solutionNitric acidSodium arsenite solution
Ammonium iron (II) sulfate solutionOxalic acid solutionSodium carbonate solution
Ammonium thiocyanate solutionPerchloric acidSodium chloride solution
Barium chloride solutionPerchloric acid in glacial acetic acidSodium hydoxide solution
Bromide bromate solutionPotassium bromate solutionSodium nitrite solution
Cerium (IV) sulfate solutionPotassium bromide bromate solutionSodium thiosulfate solution
EDTA solutionPotassium dichromate solutionSulfuric acid
Hydrochloric acidPotassium hydroxide solutionTetra-n-butylammonium hydroxide solution
Hydrochloric acid in AcetonePotassium iodate solutionTriethanolamine in Acetone*
Iodide Iodate solution*Potassium permanganate solution*Zinc sulfate solution
Iodide Iodate*Potassium thiocyanate solution* Use light shield inspection window
     
Limitations of use
Chlorinated and fluorinated hydrocarbons or chemical combinations which form deposits may make the piston difficult to move or may cause jamming.
Compatibility of the instrument for a special application (e.g., trace material analysis) must be checked by the user. For additional information, please contact the manufacturer.
The instrument is not autoclavable!
Operating limits
This instrument is designed for titrating liquids, observing the following physical limits:
  • +15 °C to +40 °C of instrument and reagent
  • Vapor pressure up to 500 mbar
  • Viscosity up to 500 mm²/s
  • Altitude: maximum 3000 m above sea level
  • Relative humidity: 20% to 90%.

Tidak ada komentar: