Details
HI1288 Multiparameter Probe
The HI1288 multiparameter probe includes pH, EC/TDS, and temperature measurement. A solid-state pre-amplifier is integrated into the probe to protect against interference from transient electrical noise.- Amperometric conductivity probe
- Built-in temperature sensor
- Easy-to-clean
- The sensor is easy to clean and maintain by design
- pH sensor with extendable cloth junction
- The HI1288 multiparameter probe features a cloth junction that can be pulled longer, effectively increasing the life of the probe
Features at-a-glance
- Easy-to-clean and maintain
- Multi-level LCD display
- On-screen tutorial messages for calibration and setup
- Automatic Temperature Compensation
- Automatic one or two-point pH calibration
- BEPS: Alerts the user in the even that low battery power could adversley affect the readings
- Battery % displayed on startup
- Compact, heavy duty, and waterproof
Specifications
pH Range 0.00 to 14.00 pH pH Resolution 0.01 pH pH Accuracy ±0.01 pH pH Calibration automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18) Conductivity Range 0 to 3999 µS/cm Conductivity Resolution 1 µS/cm Conductivity Accuracy ±2% F.S. TDS Range 0 to 2000 ppm (mg/L) TDS Resolution 1 ppm (mg/L) TDS Accuracy ±2% F.S. Temperature Range 0.0 to 60.0°C / 32.0 to 140.0°F Temperature Resolution 0.1°C / 0.1°F Temperature Accuracy ±0.5°C /±1°F Temperature Compensation pH: automatic; EC/TDS: automatic with β adjustable from 0.0 to 2.4% / °C EC/TDS Calibration automatic, one-point at: 1382 ppm (CONV=0.5), 1500 ppm(CONV=0.7), 1413 µS/cm TDS Conversion Factor 0.45 to 1.00 Electrode/Probe HI1288 PVC body, pre-amplified multiparameter probe with internal temperature sensor, DIN connector and 1m cable Battery Type/Life 1.5V (3) AAA / approximately 500 hours of continuous use; auto-off after 8 minutes of non-use Environment 0 to 50°C (32 to 122°F); RH max 100% Dimensions 152 x 58 x 30 mm (6.0 x 2.3 x 1.2”) Weight 205 g (7.2 oz.) Ordering Information HI991300 is supplied with HI1288 multiparameter probe, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI70031 1413 µS/cm calibration solution sachet, HI70032 1382 mg/L (ppm) calibration solution sachet, HI700661 electrode cleaning solution sachet, batteries, instructions and rugged carrying case.